Intended Use
The Singclean Multi-Drug One Step Test Kit utilizes the colloidal gold method to qualitatively detect the presence of drugs or drug metabolites in human urine. It is designed for preliminary screening of 23 drugs, including COC, AMP, MOP, THC, MET-OPI, BAR, BZO, MTD, MDMA, TCA, Oxy, BUP, PCP, and EDDP.
Application
This test provides visual qualitative results and is intended for use by healthcare professionals, including those at point-of-care sites, to assist in determining drug compliance.

Pack Formats
| Format | cassette, panel, and cup |
| Cassette Format | Customized, up to 6 panelspanel format: up to 16 panels |
| Cup Format | up to 18 panels |
Pack Formats
| Panel | 25 tests/box |
| Cassette | 25tests/box |
| Cup | 20 tests/box |
Test Procedure
For Test Cassette:
Place the cassette on a clean, level surface.
Using a dropper, transfer 3 full drops of urine (approx. 100 µL) into the specimen well, avoiding air bubbles.
Start the timer and wait for colored lines to appear.
Read results at 5 minutes. Do not interpret after 10 minutes.

For Test Panel:
Remove the cap and immerse the test panel vertically into the urine specimen for 10-15 seconds or until migration occurs. Ensure immersion is up to the wavy lines but not beyond the arrows.
Place the panel on a flat, dry surface and start the timer.
Read results at 5 minutes. Do not interpret after 10 minutes.

For Test Cup:
Collect urine in the cup and secure the cap tightly.
If equipped, read the temperature strip 2-4 minutes after collection to verify a range of 32-38°C.
Place the cup on a flat surface, apply the security seal with date and initials, and peel off the label to view results.
Read results at 5 minutes. Do not interpret after 10 minutes.

Interpretation of Results:
POSITIVE: One colored band in the control region (C) and no band in the test region (T). Indicates drug concentration above the cut-off level. Confirm with a more specific method.
NEGATIVE: Two colored bands in both the control (C) and test (T) regions. Indicates drug concentration below the cut-off level.
INVALID: No control band appears. Discard the result and repeat the test with a new kit. If issues persist, contact the distributor.

Test Limitations
Incorrect use may lead to insufficient samples or inaccurate results.
Unlisted substances or procedural errors may cause false results.
This test is for screening purposes only and does not determine exact drug concentration or intoxication levels.