Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home

Product Details
Customization: Available
Type: IVD Reagent
Certificates: ISO13485//Cfda
Still deciding? Get samples of US$ 4/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
420
Year of Establishment
2003-03-25
  • Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
  • Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
  • Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
  • Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
  • Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
  • Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
Find Similar Products

Basic Info.

Specimen
Urine
Form
Strip/Cassette/Uncut Sheet/Device/Midstream/Canist
Strip
2.5mm/3.0mm/3.5mm
Storage
Room Temperature
Packing
1test/Pouch
Sellf Life
2 Years
Transport Package
Cartons
Specification
5 in 1; 6 in 1; 10 in 1; 12 in 1;14 in 1 panel/cup
Trademark
Singclean or OEM brand
Origin
China
HS Code
3302100090
Production Capacity
10000/Day

Product Description

Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
Multi-drug One Step Test Kit 

(Colloidal Gold Method)
 

Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home

 

Product List

  Product Name Catalog No. Specimen Format Test/Kit Cut-off (ng/mL)
DOA Single-Drug AMP Amphetamine DAM-101/102 Urine Strip/Device 50T/40T 1000
BAR Barbiturates DBA-101/102 Strip/Device 50T/40T 300
BUP Buprenorphine DBU-101/102 Strip/Device 50T/40T 10
BZO Benzodiazepines DBZ-101/102 Strip/Device 50T/40T 300
COC Cocaine DCO-101/102 Strip/Device 50T/40T 300
COT Cotinine DCT-101/102 Strip/Device 50T/40T 200
EDDP DED-101/102 Strip/Device 50T/40T 300
FTY Fentanyl DFT-101/102 Strip/Device 50T/40T 100
KET Ketamine DKE-101/102 Strip/Device 50T/40T 1000
MDMA Ecstasy DMD-101/102 Strip/Device 50T/40T 500
MET Methamphetamine (MET/mAMP) DME-101/102 Strip/Device 50T/40T 1000
MOP Morphine 300 (OPI300) DMO-101/102 Strip/Device 50T/40T 300
MTD Methadone DMT-101/102 Strip/Device 50T/40T 300
OPI Opiate 2000 DOP-101/102 Strip/Device 50T/40T 2000
OXY Oxycodone DOX-101/102 Strip/Device 50T/40T 100
PCP Phencyclidine DPC-101/102 Strip/Device 50T/40T 25
PPX Propoxyphene DPX-101/102 Strip/Device 50T/40T 300
TCA Tricyclic Antidepressants DTC-101/102 Strip/Device 50T/40T 1000
THC M-arijuana DTH-101/102 Strip/Device 50T/40T 50
TRA Tramadol DTR-101/102 Strip/Device 50T/40T 300
DOA Multi-Drug Panel/
Device/Cup
Multi-Drug One Step Drug Screen Test Panel DOA-124 to DOA-1124 Urine 2-12 Drugs 20 Test/ box  
DUD-124 to DUD-1124 2-10 Drugs  
Multi-Drug One Step Multi-Line Drug Screen Test Device DOA-125 to DOA-1124 Urine 2-12 Drugs  
Multi-Drug Panel withIntegrated E-Z Split KeyTM Cup II DBO-127 to DBO-1127 Urine 2-12 Drugs  
DBD-127 to DBD-1107 2-15 Drugs  
Urine Adulteration Strips
(Creatinine/Nitrite/
Glutaraldehyde/
pH/Specificravity/Oxidant)
6 parameter strip DUC-111 Urine 6 parameter strip  

 

Intended use
The Multi-drug One Step Test Kit (Colloidal Gold Method) is a rapid chromatographic immunoassay for the qualitative detection for the drugs and drug metabolites in human urine. The detection limits cut-off concentrations of this test are as below list. 
Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home

Special condition for use statement(s)

Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home
Configurations of multi-drug test kit come with any combination of the above listed drug analytes with or without specimen validity test (S.V.T.). This assay provides only a preliminary analytical test result. A more specific alternative chemical method must be used to obtain a confirmed analytical result. Gas chromatography/Mass spectrometry (GC/MS) is the preferred confirmatory method. Other chemical confirmation methods are available. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

 

Pack formats

Cassette: 25 tests/box

Panel: 25 tests/box

Cup: 20 tests/box

 

Principle

The multi-drug test kit is a competitive binding immunoassay in which drugs and drug metabolites in a urine sample compete with immobilized drug conjugate for limited labeled antibody binding sites. During testing, a urine specimen migrates through the test device by capillary action. If the drug or drug metabolite concentration in the specimen is below the cut-off level, the anti-drug antibodies in colloidal gold particles will bind to the drug antigens coated in the test line of the nitrocellulose membrane to form a T line which indicates a negative result. If the concentration of drug in the urine specimen is above the cut-off level, it will bind with antibodies conjugated with colloidal gold particles, so that no T line will be developed in the test region, which indicates a positive result. A control band with a different antigen/antibody reaction is added to the immune-chrom atographic membranestrip at the control region(C) to indicate that the test has performed properly. This control line should always appear regardless of the presence of drug or drug metabolite. If the control line does not appear the test device should be discarded.


Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home


Procedure

Equilibrate the tests, urine specimens, and/or controls to room temperature (15-25ºC) prior to testing.

Remove the test from the sealed pouch and use it as soon as possible. 

For Test Cassette

• Place the Test Cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx.100L) to the specimen well (s). Avoid trapping air bubbles in the specimen well (S). 

• Start the time and wait for the colored line to appear. 

• Read the test results at 5 minutes. Do not read the results after 10minutes. 

For Test Panel

• Remove the cap from the end of the test card. With arrows pointing toward the urine specimen, immerse the test panel vertically into the urine specimen for at least 10-15 seconds. Immerse the strip(s) at least the level of the wary lines, but not above the arrow(s) on the test card.

• Place the test panel on a flat dry surface, start the time and wait for the colored line(s) to appear. Read the test results at 5 minutes. Do not read the results after 10minutes.

For Test Cup

•Collect specimen in the cup and secure the cap tightly. 

•If the temperature strip is included with Drug Test Cup, please read urine temperature between 2-4 minutes after voiding to verify the temperature ranges between 32-38ºC.

•Place the cup on a flat surface.

•Date and initial the security seal, and place the security seal on the cap.

•Peel off the label on the cup to view the results.

•Read the test results at 5 minutes. Do not read the results after 10minutes. 
Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home

Note:

•If adulteration test is included, read the adulteration strip between 3 and 5 minutes. 

See the color chart for interpretation. If the result indicates adulteration, do no interpret the drug test result and either retest the urine or collect another specimen.
 

Interpretation of results

Negative

Two distinct colored lines appear. One line should be in the control line region (C) and another line should be in the test line region (T). It indicates that the drug concentration in the urine specimen is below the designated cut-off level for the specific drug. 

Positive

Only one colored band appears in the control region (C). No apparent colored band appears in the test region (T). The absence of a line in the test region (T) indicates a positive result. The positive result indicates that the drug concentration in the urine specimen is above the designated cut-off level for that specific drug.

Invalid

The result is invalid if no colored line appears in the control line region (C), even if a line appears in the test line region (T). You should repeat the test with a new test. Ifthe problem persists, discontinue using the lot immediately and contact your local distributor.


Adulteration interpretation

(Please refer to the color chart)Semi-quantitative results are obtained by visually comparing the reacted color blocks on the strip to the printed color indicator on the color chart. No instrumentation is required.

NOTE: 

1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. If the color in test region (T) is very weak, indicating that the drug concentration in the urine specimen is close to the cut-off concentration, then the specimen needs to be detected repeatedly or confirmed by other more accurate method.

2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

 

Quality control

• Internal procedural controls are included in the test. A colored band appearing in the control region (C) is considered an internal positive procedural control. It confirms sufficient specimen volume and correct procedural technique. 

• External controls are not supplied with this kit. It is recommended that positive and negative controls be tested as a good laboratory practice to confirm the test procedure and to verify proper test performance.

 

Storage and stability

• Store in the sealed pouch at 2ºC to 30ºC.

• The test is stable through the expiration date printed on the sealed pouch.

• The test must remain in the sealed pouch until use. 

• After opening the sealed pouch, use the test as soon as possible within 60 minutes.

• Do not freeze.

• Do not use beyond the expiration date.

Singclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for HomeSingclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for HomeSingclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for HomeSingclean OEM CE Approved Wholesale Rapid Medical Ivd Diagnostic Urine Doa Test Cup for Home

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier